ʻO ke kūlana maikaʻi ʻo Copeland 1 2 3 HP Cold Room Equipment Refrigeration Condensing Unit no ka mālama ʻana i ka lumi anuanu
ʻO ka pahuhopu o kā mākou hui e hana me ka kūpaʻa, e lawelawe ana i kā mākou poʻe kūʻai aku a pau, a e hana mau ana i nā ʻenehana hou a me nā mīkini hou no ka Good Quality Copeland 1 2 3 HP Cold Room Equipment Refrigeration Condensing Unit no ka Cold Room Storage, Hoʻokipa mākou i nā mea kūʻai aku hou a me nā mea kahiko mai nā ʻano like ʻole o ke ola o kēlā me kēia lā e kamaʻilio me mākou no nā hui ʻoihana e hiki mai ana a me ka holomua like!
ʻO ka pahuhopu o kā mākou ʻoihana e hana pono, e lawelawe ana i kā mākou poʻe kūʻai aku a pau, a e hana mau ana me ka ʻenehana hou a me ka mīkini hou noʻĀpana Compressor Hau Paʻahau Kina a me nā ʻĀpana Condensing Mahana Haʻahaʻa, ʻAe ʻia nā kauoha maʻamau me nā ʻano maikaʻi like ʻole a me ka hoʻolālā kūikawā o ka mea kūʻai aku. Ke kakali nei mākou e hoʻokumu i ka laulima maikaʻi a holomua i ka ʻoihana me nā huaʻōlelo lōʻihi mai nā mea kūʻai aku o ka honua holoʻokoʻa.
ʻIkepili Hui

Wehewehe Huahana

| Hoʻohālike | ZB114KQ-TFD-558 |
| Mana lio: | 15HP |
| Ka mana hoʻoluʻolu: | 26.75-59.35KW |
| Ka hoʻoneʻe ʻana: | 43.3CBM/h |
| Uila uila: | Hoʻopilikino |
| Mea hoʻomaʻalili: | R404a/R134a/R507a/R22 |
| Mahana: | -20℃~ +10℃ |
| Mana mīkini | 15kw |
| Paipu keleawe | Φ35/φ19 |
| Papa Hoʻonohonoho Maʻamau Unit | |
| ʻAno Pahu Condenser (Wahi Hoʻoluʻu) | 160㎡ |
| Mea Hoʻokipa Refrigerant | √ |
| kiwikā Solenoid | √ |
| Kiwikā pīpī | √ |
| Papa mika kaomi kiʻekiʻe/haʻahaʻa | √ |
| Kuapo hoʻokele kaomi | √ |
| Kiwikā nānā | √ |
| Ka mika haʻahaʻa | √ |
| Ka mika kaomi kiʻekiʻe | √ |
| Nā Paipu Keleawe | √ |
| Aniani ʻIke | √ |
| Mea Hoʻomaloʻo Kānana | √ |
| Papa Mana | √ |
| kumu hoʻohālike | Mea hoʻomaʻalili | kw | Mahana hoʻopili ℃ | Ka mana hoʻoluʻu Qo (Watt) ka hoʻohana ʻana i ka mana Pe(KW) | |||||
| -12 | -10 | -5 | 0 | 5 | 10 | ||||
| ZB114KQ | R22 | Q | 30 | 26.75 | 29.05 | 35.40 | 42.50 | 50.45 | 59.35 |
| 40 | 23.20 | 25.55 | 31.70 | 38.55 | 46.10 | 54.50 | |||
| 50 |
|
| 27.05 | 33.70 | 41.00 | 48.95 | |||
| P | 30 | 7.76 | 7.79 | 7.92 | 8.09 | 8.33 | 8.63 | ||
| 40 | 9.61 | 9.63 | 9.71 | 9.83 | 9.99 | 10.22 | |||
| 50 |
|
| 12.03 | 12.09 | 12.19 | 12.34 | |||
| Mea hoʻomaʻalili | kw | Mahana hoʻopili ℃ | -20 | -15 | -10 | -5 | 0 | 5 | |
| R404A/R507 | Q | 30 | 21.90 | 27.00 | 32.75 | 39.35 | 46.80 | 55.35 | |
| 40 | 18.30 | 23.05 | 28.25 | 34.10 | 40.70 | 48.20 | |||
| 50 |
| 18.25 | 23.00 | 28.20 | 33.95 | 40.45 | |||
| P | 30 | 8.94 | 9.05 | 9.17 | 9.31 | 9.45 | 9.61 | ||
| 40 | 11.22 | 11.26 | 11.31 | 11.38 | 11.47 | 11.57 | |||
| 50 |
| 14.20 | 14.15 | 14.12 | 14.11 | 14.13 | |||
Hoʻomaopopo ʻia: ʻĀpana Condensing me ka ʻole o ka Refrigerant, Ke kauoha ʻia ka ʻāpana, ua hoʻokomo ʻia ka refrigerant e nā loea loea
Nā Pōmaikaʻi

Hiʻona

ʻAno Huahana

ʻO kā mākou huahana



No ke aha e koho ai iā mākou






ʻO ka pahuhopu o kā mākou hui e hana me ka kūpaʻa, e lawelawe ana i kā mākou poʻe kūʻai aku a pau, a e hana mau ana i nā ʻenehana hou a me nā mīkini hou no ka Good Quality Copeland 1 2 3 HP Cold Room Equipment Refrigeration Condensing Unit no ka Cold Room Storage, Hoʻokipa mākou i nā mea kūʻai aku hou a me nā mea kahiko mai nā ʻano like ʻole o ke ola o kēlā me kēia lā e kamaʻilio me mākou no nā hui ʻoihana e hiki mai ana a me ka holomua like!
Maikaʻi ka maikaʻiʻĀpana Compressor Hau Paʻahau Kina a me nā ʻĀpana Condensing Mahana Haʻahaʻa, ʻAe ʻia nā kauoha maʻamau me nā ʻano maikaʻi like ʻole a me ka hoʻolālā kūikawā o ka mea kūʻai aku. Ke kakali nei mākou e hoʻokumu i ka laulima maikaʻi a holomua i ka ʻoihana me nā huaʻōlelo lōʻihi mai nā mea kūʻai aku o ka honua holoʻokoʻa.